Before the first footing is dug, a plan drawn to scale fixes where the fire and its smoke go, how many people sleep in each room, the wall weight for the climate, the house's turn to the winter sun, the overhang for its latitude, the openings for a through-draught, the floor height, and where the animals and the latrine stand.

Tier 1 · Neolithic Shelter t1-dwelling Blocked by prerequisites
A hewn-log cabin on a stone foundation, with a shake roof and projecting eaves. The stones lift the bottom logs clear of the ground and the splash. Schorn Log Cabin · 2010-04-01 · Smallbones · Public domain · Commons ↗

Everything for this step

Field guide
Engineering → 7 sections
Builds
None yet.
Reference sheets
None.
Sciences it rests on
Physics · Astronomy · Medicine · Engineering
Track
Dwellings, level 1 of 5 · next: Permanent shelter

Why this matters

The deadliest thing in most houses is the cooking fire. Smoke from open fires and inefficient stoves killed an estimated 2.9 million people in 2021, over 309,000 of them children under five, and about 2.1 billion people still cook that way (WHO, 2025). Walls laid perfectly do not help if the hearth sits in the room where the family sleeps.

The other harms are also decided on paper, before a wall goes up. The WHO Housing and health guidelines (2018, still the current edition) record that crowding causes about 10 % of New Zealand's hospital admissions each year, cold housing about 38,200 excess winter deaths a year in 11 European countries, and damp about 15 % of new childhood asthma in Europe. The building craft is in permanent shelter and the building guide. This step decides what they build.

The shape of it

  1. Put the fire where its smoke cannot reach a sleeper: outdoors or in a separate cookhouse in warm climates, and behind a flue in cold ones. Even a vented stove leaks about 25 % of its smoke into the room (WHO).
  2. Give each person floor space: at least 3.5 m² each in a warm climate, not counting the kitchen, and 4.5–5.5 m² in a cold one (UNHCR). More than 3 people to a habitable room is overcrowding (UN-Habitat).
  3. Match wall weight to the climate: light and open where it is hot and humid; heavy, with small openings, where the days are hot and the nights fall below 20 °C; heavy inside and sun-fed where winters are cold.
  4. Turn the main openings within 30° of true south (north in the southern hemisphere), with nothing shading them from 9 a.m. to 3 p.m. in winter (US DOE).
  5. Size the overhang from the latitude: noon sun on the shortest day stands 90° − latitude − 23.45° high, on the longest 90° − latitude + 23.45°.
  6. Put openings on opposite walls, no more than 5× the ceiling height apart, with openable area at least 4 % of the floor (ASHRAE 62.1).
  7. Lift the floor above the flood mark and the splash, and put a damp-proof course under every earth wall.
  8. Keep animals in their own building and the latrine within 50 m, downwind of where people sleep.
Eave and sun on the sun-facing wall, at latitude 40° Fig 1
Earth / subsoilMasonry / brickTimberGlass
Noon sun height is 90° − latitude ∓ 23.45°: 26.55° on the shortest day and 73.45° on the longest at latitude 40°. A 0.60 m eave throws its edge shadow 0.30 m below the eave in winter, so a window whose head is there takes the full winter sun, and 2.02 m below it in summer, below the sill, so the window is in shade.

Doing it, step by step

The summary above says what has to happen. This says how, with the numbers that decide whether it works.

1 · Put the smoke outside the sleeping room

Decide where the fire goes before anything else. Household smoke killed about 2.9 million people in 2021 (WHO). Its two worst products are fine particles and carbon monoxide (WHO Housing and health guidelines, chapter 8), and in setting its limits WHO assumes that a stove with a flue still releases about 25 % of its emissions into the room (range 1–50 %). A chimney reduces the smoke but does not remove it. Plan for distance as well.

  • Warm climates: cook outdoors under a shade roof or in a separate cookhouse, as UNHCR plans for camps.
  • Cold climates: a separate kitchen room with its own door, the hearth against a stone or earth-block wall, and a hood and flue that rise clear of the roof, to the heights in the building guide. The full masonry chimney is the fireplace build.
  • Never a brazier or a banked fire in a closed sleeping room. Carbon monoxide gives no smell and no warning (fire guide).
Cooking on a clay stove in the open air in rural Bengal (2025): the smoke disperses outdoors instead of filling a room. Traditional Clay Stove Cooking in Rural Bengal · 2025-05-20 10:00:18 · Yash2025 · CC0 · Commons ↗
A log cabin with its chimney built of stone outside the gable wall, so the fire never touches the logs. First pen Carnes Cabin 4201 · 2007-10-20 10:37:27 · James Emery · CC BY 2.0 · Commons ↗
A smouldering fire or charcoal in a closed room at night can kill everyone asleep in it, with no smoke to warn them. If two people in the house wake with a headache at once, get everyone outside first.
✓ Check: On the drawn plan, no sleeping place shares a room with a fire unless a flue carries that fire's smoke out above the roof.

2 · Count the people, then size the rooms

Plan for the household five years on, not today's. WHO's first housing recommendation (strong) is to prevent and reduce crowding: the evidence linking crowding to tuberculosis and other respiratory infections is rated high certainty.

  • Floor: at least 3.5 m² of covered living space per person in a warm climate, not counting the cooking area, and 4.5–5.5 m² in a cold one, where people spend the day indoors (UNHCR, updated January 2026). The earth house, 14.4 m², sleeps four in the warm or three in the cold.
  • People per room: more than 3 per habitable room is overcrowding (UN-Habitat); the stricter American index counts more than 1 per room as crowded and more than 1.5 as severely crowded.
  • Height: at least 2 m at the lowest point in a warm climate, higher for air; no more than 2 m in a cold one, so there is less air to heat (UNHCR).
✓ Check: The plan lists every person who will live there, and the floor area divided by that number meets the UNHCR figure for the climate.

3 · Choose heavy or light walls by the climate

The day-night swing decides it. Heavy walls even out the swing; light walls let the house cool as soon as the air does. UN-Habitat's bioclimatic design guidelines (2016):

  • Hot and humid (coast, lowland tropics): a lightweight envelope, rooms one deep so air crosses each, large openings, and a raised floor to cut heat from the ground.
  • Hot and dry (desert, high swing): heavy walls and roof with a time lag of over 8 hours, small openings, compact or courtyard layouts. Close the openings by day and open them at night. This works where the night falls below 20 °C.
  • Savannah and highland: medium weight, which evens out the swing; in the highlands, let the sun in for winter warmth.
  • Cold winters: heavy floors and walls in the path of the sun store its heat (US DOE); keep windows small on the walls that face away from it. WHO proposes 18 °C indoors as safe in the cold season, and finds no demonstrable risk between 18 and 24 °C.

The building guide gives wall thickness, eave and plinth for each climate.

✓ Check: The plan names the climate type and the wall weight chosen for it, and the wall material matches the building guide's row for that climate.

4 · Find true south and turn the house to it

Plant a vertical stick on level ground and mark the tip of its shadow through the middle of the day. The shortest shadow falls at solar noon and points to the pole on your side of the equator: true north in the northern hemisphere, true south in the southern (sun geometry: PVEducation).

Then lay the long axis east–west, with the main openings in the long wall facing the sun:

  • Outside the tropics: openings within 30° of true south (north in the southern hemisphere), and nothing that shades them from 9 a.m. to 3 p.m. in winter: no tree, wall or shed in that arc (US DOE).
  • Between the tropics (latitude under 23.45°), the noon sun stands on the north side for part of the year and the south side for the rest. Keep the long walls facing north and south, keep east and west walls short with few openings, and shade every opening (UN-Habitat).
✓ Check: A peg line on the ground marks true north–south from the shortest shadow, and the planned long wall runs within 30° of east–west.

5 · Size the overhang from your latitude

Work out the noon sun height for both solstices, outside the tropics:

  • Shortest day: 90° − latitude − 23.45°
  • Longest day: 90° − latitude + 23.45°

The shadow of the eave edge falls overhang depth × tan(sun height) below the eave. Worked example at latitude 40° (north or south): the noon sun stands 26.55° high in winter and 73.45° in summer. An overhang of 0.60 m, the rain eave of the earth house, throws its edge shadow 0.30 m below the eave in winter and 2.02 m below it in summer. So a window with its head 0.30 m or more below the eave takes the full winter sun, and a sill up to 2.0 m below the eave is in shade at summer noon. Nearer the pole the winter sun is lower: at 50° the same 0.60 m eave throws a winter shadow only 0.18 m deep.

Rain sets the minimum depth, deeper in wet climates (building guide). Where rain demands a deeper eave, raise it above the window head, not the window into the shadow. East and west sun comes in low, under any eave: keep those openings small.

The Paul Schweiker House, Schaumburg, Illinois (2024): the roof projects far past the walls and shades the glass beneath it. Paul Schweiker House and Studio, Meacham Road, Schaumburg, IL · 2024-04-13 10:27:09 · w_lemay · CC BY-SA 2.0 · Commons ↗
✓ Check: At noon on the shortest day sunlight reaches the floor through the sun-facing opening, and at noon on the longest day the sill is in shadow.

6 · Place openings for a through-draught

Air crosses a room only between openings on opposite walls. The ventilation standard ASHRAE 62.1 (Addendum l, 2019), written for buildings other than homes, counts a room as naturally ventilated when:

  • Its openable area is at least 4 % of the floor: 0.58 m² for a 14.4 m² room.
  • Openings on opposite walls are no more than 5× the ceiling height apart: 12.5 m under a 2.5 m ceiling.
  • With openings on one wall only, the room reaches no deeper than 2× the ceiling height: 5 m.

Put the inlet at body height on the windward wall and the outlet opposite, with a high opening to let out warm air and smoke (UN-Habitat). Moving air brings comfort up to about 32 °C outdoors when the air is humid; above 26 °C in dry air, open at night and close by day instead. In earth walls, large openings must still keep to the earthquake opening rules of the earth house. Build very open walls as light frames.

✓ Check: Every room on the plan has openings on two opposite walls whose openable area adds up to at least 4 % of its floor.

7 · Lift the floor and stop the damp

Damp is a planning decision: about 15 % of new childhood asthma in Europe is attributed to indoor damp (WHO Housing and health guidelines). Fix three heights on the plan before any digging:

  • Floor above the design flood, with the margin fixed in the site record (choose the ground).
  • Floor above the outside ground and plinth above the splash, with a damp-proof course on the plinth and the ground falling away. The heights are in the building guide's drainage chain.
  • In hot, humid country, a floor raised clear of the ground on posts or a plinth keeps the floor cooler as well as drier (UN-Habitat).
✓ Check: The plan writes down the floor, plinth and damp-proof course heights against the site datum, and each meets the figure in the building guide.

8 · Keep animals and the latrine out of the sleeping space

Animals in their own building, not a lean-to on the house. The bugs that carry Chagas disease, which infects about 8 million people, mostly in Latin America, live in wall and roof cracks of homes and of chicken coops and pens around them (WHO, 2026). Plaster inside walls smooth with no cracks, and plan the shed, coop and dung heap downwind (animals).

Latrine: no more than 50 m from the house, so it is used at night (UNHCR), and at least 30 m from any groundwater source (UNHCR), downhill of it (latrine).

✓ Check: The plan shows the animal shed and the latrine as separate buildings, downwind, with the latrine within 50 m of the door and 30 m or more from the water.

9 · Plan out the falls and the burns

Injuries at home and in leisure kill about 110,000 people a year in Europe alone, and the WHO Housing and health guidelines recommend stair gates and window guards. Burns kill an estimated 180,000 a year, most in low- and middle-income countries; women and children are burned mostly in the kitchen, by open fires, unsafe stoves and spilled hot liquids (WHO).

  • Enclose the fire and keep its flame low; a raised or walled hearth that a crawling child cannot reach or knock over.
  • No hearth in a walkway or beside the door.
  • Guard every edge above a fall: loft openings, raised floors, ladders and stairs, with a handrail.
✓ Check: On the plan no hearth sits in a walkway, and every loft edge, stair and raised floor has a guard drawn on it.

The better path

What the record shows was done at this step, what to do instead at this tier, and the evidence. All of them: the better path.

Adopt earlier

Take the cooking fire out of the sleeping room

What was done
An open hearth on the floor of the one room where the family cooks, eats and sleeps, with the smoke left to find its way out through the thatch or a hole in the roof.
Do instead
Cook outdoors under a shade roof or in a separate cookhouse in warm climates; in cold climates give the hearth its own room and a flue, and never sleep beside a banked fire.
Evidence
WHO estimates household smoke caused 2.9 million deaths in 2021, over 309,000 of them children under five (WHO fact sheet, December 2025). Even vented stoves are assumed to release about 25 % of their emissions into the room (WHO Housing and health guidelines, 2018, table 8.7).

Needs: Fire, and keeping it, Shelter and body heat

How this fails

An open hearth in the sleeping room with only a roof hole for the smoke: the household breathes it every night, and a fire left smouldering for warmth can fill the room with carbon monoxide.
A one-room house built for three that holds eight, where one cough becomes everyone's.
Heavy, small-windowed earth walls in a hot, humid climate, which never cool at night and grow mould.
A sun-facing window under an overhang too deep to let the winter sun in, or so shallow it lets the summer sun cook the room.
Windows all on one wall, so air never crosses the room and smoke and damp stay in it.
A chicken coop or pen built against the bedroom wall, whose bugs and dung move indoors.

How you know it worked

VerificationThe plan, drawn to scale and pegged on the ground, shows the fire outside every sleeping room, at least the UNHCR floor area per person, openings on opposite walls, and an overhang that leaves the sill in shade at noon on the longest day and lets the sun onto the floor at noon on the shortest.